[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Skin effect at nonsinusiodal current
--- In femm@xxxx, V.Petoukhov <V.Petoukhov@xxxx> wrote:
> Dear Femm Community,
> who can help in question of calculating skin and proximity effects in
> wires and cables at multifrequency case (nonsinusoidal currents).
> Is any articles, books of software availible?
>
> Thank you in advance
> V. Petoukhov mailto: V.Petoukhov@xxxx
A common approximation is to compute SE and PE for each (significant)
frequency component of the input waveform then add the power loss for
each component.
Regards
Rob