[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [femm] current in slot conductors
Ahmad :
Yes ! You need to specify the slot ampere conductors seperately for the Top conductor & Bottom conductor. If you
have a 3phase wdg, I suggest you name them R_pos, R_neg and so on..... for simulating the R phase current coming out &
going into the plane of the paper.
Prem
ahmad_m_eid wrote:
> Dear all
>
> I work in linear generator field. I want to consider an ac current
> moving in the coils, so, how can I define this current value??
>
> if the rms value is 20 A and the number of turns/slot = 25
>
> so, the define current will be 20 A or 20*25 in each slot?
>
> any suggestion is helpful
>
> thanks a lot
>
> ahmad
>
>
>
>