Hi all. I am trying to calculate mutual and leakage inductances in single phase trasformer as in attached file. I have modeled this transformer with core EI having a cross section of 50x80 mm, 220 turns at the primary and 117 turns at secondary. The core extends 0.08m in the into-the-page direction. I also added a small gap between E and I to be sure that there is no relevant saturation. First i evaluated the self inductance Ls1 = 290.6mH and Ls2 = 82.2 mH using A,J integral as explained in tutorial. I set primary windings to circuit primary+ and primary- having + or - 10A, so the current I1 is 10/220 = 45.45 mA Then i turned off primary winding and set secondary to a circiut carring 10 A. Theese results are in according with the classical formulas. Then i evaluated mutual inductance as described in Femm manual at page 34. N2= 117 , I1=10/220 , a2 = 1.139E-3 m², integ A1dV2 = 4.339E-7 but the result was M = 77.1 mH ( i multiplied the integ x 0.08 , the 3 dimension of core ) So the cooupling factor k = M / sqr(L1*L2) = 0.498 that is wrong. ( I think k is near 1 ) What is wrong in this model ? Can someone help me ? Best regards Fabio
Attachment:
bin00059.bin